SUP-PH-EPR

Rated Current
5A to 30A
Test Voltage
Line to Line
1,000VAC 50/60Hz 60 sec
Line to Case
2,000VAC 50/60Hz 60 sec
Insulation Resistance
Line to Case
6,000MΩ min (at 500VDC)
Leakage Current (max)
0.6mA (at 250VAC 60Hz)
Voltage Drop (max)
1.0VAC
Temperature Rise (max)
35K
Insertion Losses
Normal Mode (MHz)
0.5 ~ 30
Common Mode (MHz)
0.2 ~ 30
Operating Temperature
-25~+50°C

Features

  • Low range high attenuation effects by super high µ material (20~30dB at 10,000Hz)
  • Excellent pulse absorption (more than 25dB attenuation with 1,500V pulse)
  • Three terminal styles: Faston™, solder or screw
  • Bleeder resistor for electric shock protection

Applications

Information processing devices (for Europe), office appliances and various control systems.